BKQRX - DOWFROST HD INHIBITED PROPYLENE GLYCOL, 046
- MSDS: BKQRX
- Manufacturer: DOW CHEMICAL USA
- Product Name: DOWFROST HD INHIBITED PROPYLENE GLYCOL, 046
- National Stock Number: 6505-00N017202
Product Identification
Product ID:DOWFROST HD INHIBITED PROPYLENE GLYCOL, 046
MSDS Date:03/20/1988
FSC:6505
NIIN:00N017202
MSDS Number: BKQRX
Responsible Party
MIDLAND, MI 48674
US
Emergency Phone: 517-636-4400
Info Phone: 517-636-4400
Cage: EO044
Contractor
Telephone: 800-258-2436
Cage: EO044
Ingredients
1,2-PROPANEDIOL(PROPYLENE GLYCOL)
CAS: 57-55-6
RTECS: TY2000000
Fraction By Weight: 75%
DIPOTASSIUM PHOSPHATE
CAS: 7758-11-4
Fraction By Weight: <5%
WATER (DEIONIZED WATER)
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: BAL.
Hazards
LD50 LC50 Mixture:(ORAL/RAT) 21-33.7 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: MAY CAUSE SLIGHT TRANSIENT (TEMP)
IRRIT. CORNEAL INJURY IS UNLIKELY. SKIN: PRLNG CONT IS ESSENTIALLY
NON-IRRIT. A SINGLE PRLNG EXPOS IS NOT LIKELY TO RSLT IN THE MATL
BEING ABSORBED THROUGH SKIN IN HARMFUL AMTS. RPTD EXPOS MAY CAUSE
SLIGHT FLAKING, TENDERNESS & SOFTENING OF SKIN. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: INGEST: SINGLE DOSE ORAL TOX IS LOW.
NO HAZ ANTICIPATED FROM INGEST INCIDENTAL TO INDUS EXPOS. INHAL: A
SINGLE PRLNG EXPOS IS NOT LIKELY TO CAUSE ADVERSE EFTS. MISTS ARE
NOT LIKELY TO BE HAZ . SYSTEMIC/OTHER EFTS: RPTD EXCESSIVE INGEST
MAY CAUSE CNS EFTS. DID NOT CAUSE CANCER IN LONG-TERM ANIMAL (SUPP
DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE: IRRIGATE IMMED W/WATER FOR AT LEAST 15 MIN. SKIN: WASH
OFF IN FLOWING WATER OR SHOWER. INGEST: CALL MD IMMEDIATELY .
INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP)
(FP N ). NOTE TO MD: NO SPECIFIC ANTIDOTE. SUPPORTIVE CARE.
TREATMENT BASED ON JUDGMENT OF THE MD IN RESPONSE TO REACTIONS OF
THE PATIENT.
Fire Fighting
Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:WATER FOG, DRY CHEMICAL, ALCOHOL FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:COVER WITH ABSORBENT MATERIAL, SOAK UP AND
SWEEP INTO BAGS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:ATMOSPHERIC LEVELS SHLD BE MAINTAINED BELOW THE
EXPOS GUIDELINE. WHEN RESP PROT IS REQD FOR CERTAIN OPERATIONS, USE
NIOSH/MSHA APPRVD AIR-PURIFYING RESPIRATOR.
Ventilation:GOOD GENERAL VENTILATION SHOULD BE SUFFICIENT.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: STUDIES. BIRTH DEFECTS ARE UNLIKELY. EXPOSURES HAVING
NO ADVERSE EFTS ON THE MOTHER SHLD HAVE NO EFT ON THE FETUS. IN
ANIMAL STUDIES, HAS BEEN SHOWN NOT TO INTERFERE W/REPRODUCTION. R
SLT OF IN VITRO (TEST TUBE) MUTAGENICITY TESTS HAVE BEEN NEGATIVE.
RSLT OF MUTAGENICITY TESTS IN ANIMALS HAVE BEEN NEG.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:240F,116C
Vapor Pres:13.6
Vapor Density:>1
Spec Gravity:1.050
Solubility in Water:COMPLETE
Appearance and Odor:BRIGHT YELLOW LIQUID, ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIAL.
Stability Condition to Avoid:TEMPERATURES >450F.
Hazardous Decomposition Products:NONE.
Disposal
Waste Disposal Methods:INCINERATE OR BURY AWAY FROM WATER SUPPLIES IN
ACCORDANCE WITH APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.